Dell Compellent Series 30 User Manual
Page 184

176
Storage Center 5.5 System Manager User Guide
Controllers
A
Figure 144. Advanced iSCSI Remote Connection
b Keep or change any of the following:
•
Port number
•
Enable or disable data digest
•
Enable or disable header digest
•
Enable or disable immediate data
•
Select a window size, from 16KB to 2048 KB
•
Select a keep alive time-out, from 3 seconds to 18 hours
•
Select a SCSI command data time-out, from 3 seconds to 18 hours
c Click Continue. If the Link Speed window reappears. Click Continue again. The
Add Remote System confirmation window appears.
9 Click Add Now. The local system now recognizes the remote system. But before the
Remote System configuration is complete, you must log into the remote system and
identify the local system.
10 To identify the local system to the remote system:
a Log into the remote system.
b Repeat the steps described in
Adding a Remote System to iSCSI Ports on page 174
.
Viewing Remote iSCSI Connections – Virtual Ports Not Enabled
1 In the system tree, select an iSCSI card. The iSCSI information window appears.
2 Click the Remote Compellent Connections tab. The Remote Compellent iSCSI
Connections window appears.