Using the System Setup Program
7 In the Remote Access Configuration screen, verify the following settings:
• Remote Access: Enabled
• Serial port number: COM2 as SOL
• Serial Port Mode: 115200 8,n,1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 106 for details. Make sure the
last four options syncs with the host and client.
8 In the Server screen, select BMC LAN Configuration and press
9 In the BMC LAN Configuration screen, verify the following settings:
• BMC LAN Port Configuration: Dedicated-NIC
• BMC NIC IP Source: DHCP or Static (Use DHCP if your network
servers are using automatic assignment of IP addresses)
• IP Address: 192.168.001.003
• Subnet Mask: 255.255.255.000
• Gateway Address: 000.000.000.000
See "Set BMC LAN Configuration" on page 104 for details. Make sure the
host and client are on the same network
10 Press
and a message prompts you to save the changes.
To activate console redirection via a shared BMC management port, you must
configure the following settings:
1 Connect the internal BMC cable to the sled. See "Installing the BMC
Management Cable" on page 316.
2 Connect the network cable to the server enclosure’s Ethernet connector or
BMC management port. See Figure 1-6 or Figure 1-7 for network cable
connection in shared-NIC mode.
3 Press
Setup.
4 In the System Setup screen, select the Server menu and press