See "enabling and configuring – Dell PowerEdge C8000 User Manual
Page 63
Using the System Setup Program
63
5 In the Remote Access Configuration screen, verify the following settings:
• Remote Access: Enabled
• Serial port number: COM2 as SOL
• Serial Port Mode: 115200 8,n,1
• Flow Control: None
• Redirection After BIOS POST: Always
• Terminal Type: ANSI
See "Remote Access Configuration" on page 106 for details. Make sure the
host and client are on the same network.
6 Press
and a message prompts you to save the changes.
Enabling and Configuring Console Redirection Via BMC SOL
When using the BMC management port, you have two options for
connecting and managing servers: Dedicated-NIC mode and Shared-NIC
mode. The following procedures show the setup option of the BMC
management port through a Dedicated-NIC or Shared-NIC.
To activate console redirection via a dedicated BMC management port, you
must configure the following settings:
1 Connect the internal BMC cable to the sled. See "Installing the BMC
Management Cable" on page 316.
2 Connect the network cable to the sled’s BMC management port. See
Figure 1-5 for network cable connection in dedicated-NIC mode.
3 Turn on or restart your system.
4 Press
Setup.
5 In the System Setup screen, select the Server menu and press
6 In the Server screen, select Remote Access Configuration and press