Power and system board indicator codes – Dell PowerEdge C8000 User Manual
Page 29
About Your System
29
* This condition is not supported in LSI HBA/RAID cards. When you abort the RAID rebuild process,
the hard-drive LED blinks amber to indicate drive failure.
This LED pattern is not applicable for the non-RAID mode of onboard SATA, for example, without Intel
RSTe drivers.
Power and System Board Indicator Codes
The indicators on the front of the sled display status codes during system
startup. For location of the indicators on the front panel, see Figure 1-1.
Predicted drive failure (SMART)
On 500 ms
Off 500 ms
Off 1000 ms
Off 500 ms
On 500 ms
Off 1000 ms
Drive rebuilding aborted*
On 3000 ms
Off 9000 ms
Off 6000 ms
On 3000 ms
Off 3000 ms
Table 1-1. Power and System Board Indicator Codes
Indicator
Color Status
Indicator
Code
Power-on
indicator
Green
Solid
Sled power is on (S0)
Amber
Off
Green
Solid
BMC critical condition event in power off
mode (S4/S5)
Amber
Blinking
Green
Off
BMC critical condition event in power on
mode (S0)
Amber
Blinking
System
identification
indicator
Blue
Solid
The IPMI via Chassis Identify Command On
or ID Button Press ID On is generated
Blue
Blinking Only the IPMI via Chassis Identify Command
Blink On is generated
Off
The IPMI via Chassis Identify Command Off
or ID Button Press ID Off is generated
Condition
(continued)
Hard-Drive LEDs
(HDD0 to HDD7)
Green LED
Amber LED