Midi data format, 2 function call – library store, recall – Yamaha LS9 User Manual
Page 263
MIDI Data Format
263
LS9-16/32 Owner’s Manual
Appendices
4.1.2
Format (PARAMETER REQUEST)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed via PARAMETER CHANGE immediately the data is
received.
4.1.3
Data category
4.2 FUNCTION CALL – LIBRARY STORE, RECALL –
4.2.1 Format (PARAMETER CHANGE)
Receive
Data will be received when [PARAMETER CHANGE Rx] is on and the Device
number of both [Rx CH] and SUB STATUS are matched. The data will be
echoed when [PARAMETER CHANGE ECHO] is on. The corresponding
parameter will be changed immediately the data is received.
Transmission
Data will be transmitted with the [Device Number] (MIDI CH) in [Tx CH]
when [PARAMETER CHANGE Tx] is on.
4.2.2
Function Name
4.2.3
Module Name
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0001nnnn 3n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00010010 12
LS9
DATA Category 0ccccccc cc
DATA
0eeeeeee eh
Element no High.
0eeeeeee el
Element no Low.
0iiiiiii ih
Index no High.
0iiiiiii il
Index no Low.
0ccccccc ch
Channel no High.
0ccccccc cl
Channel no Low.
EOX
11110111 F7
End of exclusive
DATA CATEGORY
NAME
0x01
00000001
Current Scene/Setup/Backup/
User Setup Data
STATUS
11110000 F0
System exclusive message
ID No.
01000011 43
Manufacture’s ID number (YAMAHA)
SUB STATUS
0001nnnn 1n
n=0-15 (Device number=MIDI Channel)
GROUP ID
00111110 3E
Digital mixer
MODEL ID
00010010 12
LS9
DATA CATEGORY 00000000 00
OTHER DATA
FUNCTION NAME 01001100 "L"
(ASCII CODE)
01101001 "i"
(ASCII CODE)
01100010 "b"
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
0fffffff ff
(ASCII CODE)
MODULE NAME
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
0mmmmmmm mm
(ASCII CODE)
DATA
0nnnnnnn nh
Number High
0nnnnnnn nl
Number Low
0ccccccc ch
Channel High
0ccccccc cl
Channel Low
EOX
11110111 F7
End of exclusive
FUNCTION NAME
Store
“LibStr__”
Recall
“LibRcl__”
Unknown Factor Store
“LibUnStr”
Unknown Factor Recall
“LibUnRcl”
Store Undo (only Scene)
“LibStrUd”
Recall Undo (only Scene)
“LibRclUd”
MODULE NAME
Scene
“SCENE___”
Input EQ
“INEQ____”
Output EQ
“OUTEQ___”
Dynamics
“DYNA____”
GEQ
“GEQ_____”
Effect
“EFFECT__”
Function
Number
channel*1)
tx/rx
“LibStr__“
SCENE
1- 300
*5)
tx/rx
INPUT EQ LIB
41- 199
*1)
tx/rx
OUTPUT EQ LIB
4- 199
*2) *3) *4)
tx/rx
Dynamics LIB
42- 199
*1) *2) *3) *4) *8)
tx/rx
GEQ LIB
1- 199
*6)
tx/rx
EFFECT LIB
58- 199
*7)
tx/rx
“LibUnStr“
SCENE
1- 300
0
tx
INPUT EQ LIB
41- 199
0
tx
OUTPUT EQ LIB
4- 199
0
tx
Dynamics LIB
42- 199
0
tx
GEQ LIB
1- 199
0
tx
EFFECT LIB
58- 199
0
tx
“LibRcl__“
SCENE
0- 300
*5)
tx/rx
INPUT EQ LIB
1- 199
*1)
tx/rx
OUTPUT EQ LIB
1- 199
*2) *3) *4)
tx/rx
Dynamics LIB
1- 199
*1) *2) *3) *4) *8)
tx/rx
GEQ LIB
0- 199
*6)
tx/rx
EFFECT LIB
1- 199
*7)
tx/rx
“LibUnRcl“
SCENE
0
*5)
tx
INPUT EQ LIB
0
*1)
tx
OUTPUT EQ LIB
0
*2) *3) *4)
tx
Dynamics LIB
0
*1) *2) *3) *4) *8)
tx
GEQ LIB
0
*6)
tx
EFFECT LIB
0
*7)
tx
“LibStrUd“
SCENE
0
0
“LibRclUd“
SCENE
0
0
*1) 0:CH1–63:CH64
64:ST IN 1L–71:ST IN 4R
*2) 256:MIX1–271:MIX16
*3) 512:MATRIX1–519:MATRIX8
*4) 1024:STEREO L–1026:MONO(C)
*5) 512:will be used if the recalling or storing data is only one.
*6) 0:RACK1–7:RACK8 If a GEQ is mounted in RACK 1–8.
*7) 0:RACK5–3:RACK8 If an effect is mounted in RACK 5–8.
*8) 1280:CH 1–1343:CH 64
1344:STIN 1L–1351:STIN 4R
(Dynamics2)