Level diagram – Yamaha LS9 User Manual
Page 288
Max. DSP Noise Floor
AD
Max. Output
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
Digital
Bit
34
35
36
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
-170
-190
-200
-210
GAIN
dBu
Analog
dBFS
-180
[0dBu = 0.775Vrms]
[0dBFS = Full Scale]
+20
+10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
+24
+4
-170
-180
-190
Digital
Analog
Digital
Analog
dBu
Analog
+20
+10
0
-10
-20
-30
-40
-50
-60
-70
-80
-90
-100
-110
-120
-130
-140
-150
-160
+24
+4
-170
-180
-190
Nominal Output
[+24dBu]
[+4dBu]
+30
+30
OMNI OUT1-16/8
[Default setting]
Nominal Output
(75mW@8
Ω)
(150mW@8
Ω)
Max Output
[The position of the level
control is 10dB lowered
from Max]
PHONES
INPUT 1-32/16 (GAIN MIN.)
1
2 INPUT 1-32/16 (GAIN MAX.)
Nominal Input [-62dBu]
Max. Input [-42dBu]
Nominal Input [+10dBu]
Max. Input [+30dBu]
DELAY
OUTPUT
PATCH
ATT.
EQ
(x4)
DYN
ø,ATT,
TRIM
DA
INSERT
MASTER
LEVEL
/ BAL
MASTER
ON
INPUT
PATCH
HPF
ATT.
ON
PAN
BUS
Adder
LEVEL
EQ
(x4)
ø
DYN
1
DYN
2
INSERT
INSERT
Digital Clipping Level
IN
OUT
IN
OUT
IN
OUT
CASCADE OUT
CASCADE IN
1
1
2
2
■
LS9-16/LS9-32
Level Diagram