beautypg.com

Using the recall safe function, Recall safe screen, P. 140) – Yamaha LS9 User Manual

Page 140: Ations, E function

background image

140

Using the Recall Safe function

LS9-16/32 Owner’s Manual

“Recall Safe” is a function that excludes only specific parameters/channels from Recall opera-
tions. This differs from the Focus settings (

→ p. 139) made for individual scenes in that Recall

Safe settings are common to all scenes.

1

In the DISPLAY ACCESS section, press the
[CHANNEL JOB] key repeatedly to access
the RECALL SAFE screen.

In this screen you can make settings for the Recall
Safe function. The window contains the following
items.

1

CH RECALL SAFE field

The channels for which Recall Safe is turned on are
highlighted in this field. If you turn on the SET BY
SEL button, you can turn on Recall Safe for a channel
simply by pressing the [SEL] key of that channel.

B

CLEAR ALL button

This clears all Recall Safe settings for the channels
that are highlighted in the CH RECALL SAFE field.

C

GLOBAL field

In this field, global parameters (parameters that affect
the entire mix, and are not specific to individual chan-
nels) can be excluded from Recall operations.

D

SAFE PARAMETER field

Here you can switch Recall Safe on/off for each chan-
nel, and choose the parameters that will be excluded
from Recall operations. If you select a channel by
pressing its [SEL] key, the Recall Safe settings of that
channel will be shown in this field.

E

APPLY TO ALL INPUT button / APPLY TO
ALL OUTPUT button

If these buttons are on when you operate the SAFE
PARAMETER buttons, the changes will apply to all
input (or output) channels. This is convenient when
you want to make settings for all channels in a single
action.

2

To select the channel whose Recall Safe
settings you want to edit, press the corre-
sponding [SEL] key.

The corresponding channel in the CH RECALL SAFE
field will be enclosed by a white border. (However,
Recall Safe is not yet enabled at this point.) At this
time, the SAFE PARAMETER field will show the
Recall Safe settings of the selected channel.

Using the Recall Safe function

[CHANNEL JOB] key

LS9-16

LS9-32

1

2

4

5

3

1

2

4

5

3

• You can also access this screen from the SAFE field of the

SELECTED CH VIEW screen (

p. 88).

HINT

• If the CH RECALL SAFE field’s SET BY SEL button is on,

Recall Safe will be enabled when you press the [SEL] key,
and the corresponding channel will be highlighted in the CH
RECALL SAFE field. You can select parameters as described
in step 3 even after turning Recall Safe on.

HINT