Adjusting the faders (calibration function) – Yamaha LS9 User Manual
Page 223
223
Adjusting the faders (Calibration function)
LS9-16/32 Owner’s Manual
20
Other functions
Depending on the environment in which you use the console, discrepancies may occur in the
motion of the motor faders. You can use the Calibration function to correct these discrepancies.
1
While holding down the [SCENE MEMORY]
key of the DISPLAY ACCESS section, turn
on the power.
After the opening screen, the following startup menu
screen will appear.
1
FADER CALIBRATION button
2
Move the cursor to the FADER CALIBRA-
TION button and press the [ENTER] key.
The FADER CALIBRATION MODE popup window
will appear, where you can adjust the faders.
3
Use the top panel [SEL] keys to select the
fader for which you want to perform calibra-
tion.
Fader calibration is performed semi-automatically for
the faders you specify using their [SEL] keys. Each
fader selected by its [SEL] key is shown in red in the
popup window.
4
Move the cursor to the START button and
press the [ENTER] key.
A dialog box will ask you to confirm the operation.
5
Move the cursor to the OK button of the
dialog box and press the [ENTER] key.
Each of the specified faders will move to the target
positions in the following sequence.
1
-
∞
(push down to the minimum value)
B
-20 dB
C
0 dB
D
+10 dB (push up to the maximum value)
6
If there are any faders that are not in the
positions shown in the screen, manually
move them to the appropriate position.
7
When you have set all faders to the target
location, move the cursor to the OK button
and press the [ENTER] key.
The process will proceed to the next fader position.
8
Repeat steps 6–7 to adjust the faders for
positions
1 through 4.
9
When you have finished the calibration pro-
cess and the APPLY button has appeared,
move the cursor to the APPLY button and
press the [ENTER] key.
The calibration settings will be saved in internal mem-
ory.
10
Move the cursor to the EXIT button and
press the [ENTER] key.
The console will start up in normal operating mode.
Adjusting the faders (Calibration function)
1
• This window will also appear if a problem is detected in the
fader settings while the LS9 is started up.
HINT
• If the RESTART button appears when calibration ends, cali-
bration has failed. Move the cursor to the RESTART button
and press the [ENTER] key to execute calibration once again.
NOTE
• Alternatively, you can continue by selecting a different menu
instead of using the EXIT button.
HINT