The following are the possible resolver settings:
Parameter 272 [Reslvr0 SpdRatio] specifies the speed ratio for the resolver option
card at port 0. The speed ratio comes from the following formula:
Speed ratio = electrical rev.s / mechanical rev.s = pole count / 2
Parameter 273 [Reslvr0 Carrier] specifies the resolver carrier frequency for the
resolver option card at port 0.
Parameter 274 [Reslvr0 In Volts] specifies the resolver input voltage for the
resolver option card at port 0.
Parameter 275 [Rslvr0 XfrmRatio] specifies the resolver transformation ratio for
the resolver option card at port 0.
Parameter 276 [Reslvr0 CableBal] specifies the resolver cable balance for the
resolver option card at port 0.
Parameter 269 [Resolver0 Status] indicates status of the resolver option card port
0. The bits are defined as follows:
• Bit 0 “-Cable Tune” indicates a cable tune is in progress.
• Bit 1 “-Tune Result” indicates the tuning parameter type. When set, it
indicates the tuning is using the parameter database. When cleared, it
indicates the tuning is using derived data.
• Bit 2 “-Mtr Turning” indicates that the motor is turning.
• Bit 3 “-Cable Comp”
Par 277
[Reslvr0 Type Sel]
Par 272
[Reslvr0 SpdRatio]
Par 273
[Reslvr0 Carrier]
Par 274
[Reslvr0 In Volts]
Par 275
[Reslvr0 XfrmRatio] Description
0 - Disabled
1
0
0
0.0
No resolver configured
1 -T2014/2087x1
1
2381
26
0.4538
Tamagawa, TS-2014N181E32, TS-
2087N1E9, TS-2087N11E9
2 -T2014/2087x2
2
2381
26
0.4538
Tamagawa, TS-2014N182E32, TS-
2087N2E9, TS-2087N12E9
3 -T2014/2087x5
5
2381
26
0.4538
Tamagawa, TS-2014N185E32, TS-
2087N5E9
4 - MPL 460v
1
4000
8
0.25
AB Motor with integrated Resolver
5 - Reserved
1
9300
22
0.5
Not supported
6 - Siemens 1FT6
1
4000
5
0.5
Siemens, 1FT6 series Motors with
integrated Resolver
7 - PrkrHn ZX600
1
7000
4.25
0.4706
Parker Hannifin, ZX600 series Motor with
integrated Resolver
8 - Reserved
1
2500
12
0.5
Not Supported for Speed Regulation
9 - 1326Ax 460v
1
4000
8
0.25
AB Motor with integrated Resolver
10 - Reserved
1
9000
15.5
0.5013
Not Supported for Speed Regulation
11 - Reserved
1
2500
7
1.7
Not Supported for Speed Regulation
12 - Reserved
1
9300
22
0.5
Not Supported for Speed Regulation
13 - Reserved
1
2000
6.36
0.5
Not Supported for Speed Regulation
14 - AmciR11XC107
1
2381
26
0.4538
Advanced Micro Controls, R11X-C107
15 - PowerTec R1
–
–
–
–
Not Used
16 - PowerTec R1
–
–
–
–
Not Used