• Bits 10…12 “SmplRate btx”, configure the sample interval for measuring
speed (see
below). Increasing the encoder sample interval
improves speed measurement near zero speed. Decreasing allows the speed
control regulator to perform with high gains at high speeds.
Table 19 - Resolution Settings
Table 20 - Resolution and Least Significant Bits Used
The following table shows the maximum RPM of the motor depending on
resolution setting:
Table 21 - Resolution and Resolver Tracking Speed
Table 22 - FIR Filter Settings
Parameter 277 [Reslvr0 Type Sel] specifies the type of resolver. [Reslvr0 Type Sel]
automatically sets parameters 272 [Reslvr0 SpdRatio] through 276 [Reslvr0
CableBal]. Parameters 273 [Reslvr0 Carrier] through 276 [Reslvr0 CableBal]
cannot be changed by the user.
Bit
Resolution
3 2
0 0 10 bits
0 1 12 bits (default setting)
1 0 14 bits
1 1 16 bits
Resolution LSB Not Used Parameter 250 Increments by
16 bits
All bits used
1
14 bits
2 LSB not used
4
12 bits
4 LSB not used
8
10 bits
6 LSB not used
64
Resolution
Maximum Carrier
Frequency
Tracking Speed for
X1 Resolver
Tracking Speed
for X2 Resolver
Tracking Speed
for X5 Resolver
10 bits
34 kHz
55 K-rpm
27.5 K-rpm
11 K-rpm
12 bits
24 kHz
13.8 K-rpm
6.9 K-rpm
2.76 K-rpm
14 bits
14 kHz
3480 rpm
1740 rpm
696 rpm
16 bits
10 kHz
900 rpm
450 rpm
180 rpm
Bit 12/28 11/27 10/26
Number of Taps
0
0
0
1
0
0
1
2
0
1
0
4
0
1
1
8
1
0
0
16
1
0
1
32
1
1
0
64
1
1
1