Figure A.11 illustrates addressing 4 modules, each with the same I/O group
number, but in four different racks of a single I/O chassis. (This method is
explained in Figure A.11.)

Figure A.11

Group Address of a Module in Four Different Racks

Н

Н

Н

Rack 1

I/O Group No.

0Ć3

4Ć7

0Ć3

4Ć7

0Ć3

4Ć7

0Ć3

4Ć7

I/O Group 1

Address

1 1 1

I/O Group 1

Address

121

Input
Rack

I/O Group

I/O Group 1

Address

131

I/O Group 1

Address

141

Rack 2

Rack 3

Rack 4

NOTE: When addressing a one-block transfer module, it must be
addressed by the lowest group number that it occupies and at slot 0. For
example, a one-slot block transfer module in rack 1, group 2 and 3 (chassis
slot 2) would be addressed (by Rack-Group-Slot) at location 120.

NOTE: When addressing a two-slot block transfer module, it too must be
addressed by the lowest group number that it occupies and at slot 0. For
example, a two-slot block transfer module in rack 3, groups 4, 5, 6, and 7
(it occupies chassis slots 3 and 4) would be addressed (by Rack-Group-
Slot) at location 340.