beautypg.com

Rockwell Automation 1772-LP3 PLC - 2/30 Programmable Controller Programming and Operations Manual User Manual

Page 272

background image

Sequencer Instructions

Chapter 15

15Ć9

the data monitor display of a sequencer instruction and a file instruction
should be noted. The Sequencer Output instruction will be used as an
example. Each column in the sequencer table represents the data for each
output word. This data controls the outputs of the corresponding output
word at each step in the sequencer operation. The status of the outputs can
be observed in the output address data displayed in the header.

In contrast, each column in a File instruction display represents a complete
file. File data is manipulated by the instruction. The result of the
instruction operation is contained in the result file or in a specified word
address of the instruction.

Figure 15.8

Example Binary Data Monitor Display of a SEQUENCER OUTPUT

BINARY DATA MONITOR

SEQUENCER OUTPUT

COUNTER ADDR: 054

STEP: 008

SEQUENCER LENGTH: 009

FILE: 600Ć621

OUTPUT ADDR:

011

013

DATA:

11110000 11000011

11111100 00011000

MASK ADDR:

211

212

DATA:

11111111 11111111

11111111 11000000

STEP

WORD 1

WORD 2

001

00110101 11000101

11111111 11111111

002

01110100 00011101

00010111 00110011

003

10101111 00010101

11101011 11010100

004

11000000 00000011

10100001 01010001

005

00010100 00010111

10101111 11010101

006

01110101 11101011

11101011 11101000

007

11101110 11101000

00011111 11110011

008

11110000 11000011

11111100 00011000

009

00011111 11110111

11010111 10101111

DATA: 11111111 11111111

PROGRAM MODE

Field

Cursor

Digit

Cursor