Multi-console and Synchronized Backup
359
Network Type
This setting adjusts the timeout period before a backup device will take control from the master.
• Standard - After five seconds of no response from the master, the backup will assume the
master has disconnected and will then take control.
• Engineered - After 1.6 seconds of no response from the master, the backup will assume the
master has disconnected and will then take control.
Change IP Address
www.etcconnect.com/
wiki
.
Default Ion Console IP Address:
10.101.100.101
Default Ion RPU IP Address:
10.101.95.101
Each Ion device on the network should be given a unique IP address. If running multiple devices of
the same type (for example - two consoles, or two RPUs), you must alter the default static IP
addresses to ensure proper functionality.
Changing the static IP address is done through the ECU (see
), on the
“Network” page. Manually change the IP address of any non-primary Ion device by clicking in the IP
Address field and entering the new number from the keyboard. When done, press [Enter].
N o t e :
It is recommended that you alter the very last digit of the static IP address by an
increment of one for each additional Ion device on the network. Therefore, if the
master ends in “101”, change the backup to end in “102”, a client to end in “103”