N o t e – ETC Ion User Manual
Page 289

21
Using About
273
{Dimmer Feedback} - appears when the current address is patched to a dimmer in an ETC Sensor
rack with a CEM+ or CEM3. Sensor feedback must be enabled. See
and
for more information.
{Dimmer Feedback} displays the following information:
•
Name (dimmer name)
•
Module type
•
Rack/Position
•
Rack dimmer level (displayed as a percentage)
•
Rack dimmer source
•
Recorded load
•
Actual load
{Dimmer Feedback} displays the following information, which can be modified from Ion by clicking
on the value and entering in a new value:
•
Firing Mode
•
Control Mode
•
Curve
•
Threshold
•
Scale Minimum
•
Scale Maximum
•
Preheat Enable
•
Preheat Timing
•
Advanced Features (AF) Enable
Ion supports the following softkey commands from this display:
•
{Ignore Errors}
•
{Clear Errors}
N o t e :
For Sensor feedback, the CEM+ must be running software version 3.0 or later.
N o t e :
Clearing CEM+ / CEM3 errors from Ion will be temporary unless the errors have
been fixed at the CEM+ / CEM3 Errors displayed on Ion will clear on their own
once they have been cleared from the CEM+ / CEM3. Some CEM+ / CEM3 errors
can only be cleared at the CEM+ / CEM3.