3 fuel run solenoid – SkyTrak 6036 Service Manual User Manual
Page 290
Section 10.
Electrical System
10-28
Model 6036/6036T S/N 9B0500 thru 14833
1.
Neutral Start Switch
2.
Switch Actuating Pin
3.
Control Valve Housing Assembly
4.
Forward, Neutral and Reverse Valve Spool
5.
Oil Seal
6.
Valve Spool Stop
Fig. 10.19 Neutral Start Switch
1
2
1.
Fuel Injector Pump
2.
Fuel Run Solenoid
NEUTRAL START
SWITCH
HYDRAULIC
DECLUTCH
SWITCH ACTUATING PIN
MA1231
MA1242
10.7.3
Fuel Run Solenoid
The fuel run solenoid valve (2, Fig. 10.20) lets fuel
enter the injection pump when the ignition key is
turned to START or RUN. Use the figure below to
determine the location and style of the fuel injector
pump on your engine. The fuel run solenoids are
located as follows:
Perkins - On the side of the pump.
Cummins Turbo (S/N 3616 & Before) - On the top
front of the pump.
Cummins Naturally Aspirated - On the bottom
toward the front of the pump.
Cummins Turbo (S/N 3617 & After) - The assem-
bly is bolted to the backside of the injector pump
and connected to a mechanical linkage.
MA6200
Fig. 10.20 Fuel Run Solenoid
CUMMINS - TURBO
(S/N 3616 & BEFORE)
BOSCH INJECTOR PUMP
CUMMINS -
NATURALLY
ASPIRATED
ENGINES
LUCAS
INJECTOR
PUMP
CUMMINS -
TURBO (S/N 3617
& AFTER)
BOSCH
INJECTOR PUMP
PERKINS
ENGINES ONLY
1
2
1
2
1
2
LOCATED
BEHIND FUEL
INJECTOR
PUMP