Section 10.

Electrical System

10-28

Model 6036/6036T S/N 9B0500 thru 14833

1.

Neutral Start Switch

2.

Switch Actuating Pin

3.

Control Valve Housing Assembly

4.

Forward, Neutral and Reverse Valve Spool

5.

Oil Seal

6.

Valve Spool Stop

Fig. 10.19 Neutral Start Switch

1

2

1.

Fuel Injector Pump

2.

Fuel Run Solenoid

NEUTRAL START

SWITCH

HYDRAULIC

DECLUTCH

SWITCH ACTUATING PIN

MA1231

MA1242

10.7.3

Fuel Run Solenoid

The fuel run solenoid valve (2, Fig. 10.20) lets fuel
enter the injection pump when the ignition key is
turned to START or RUN. Use the figure below to
determine the location and style of the fuel injector
pump on your engine. The fuel run solenoids are
located as follows:
Perkins - On the side of the pump.

Cummins Turbo (S/N 3616 & Before) - On the top
front of the pump.

Cummins Naturally Aspirated - On the bottom
toward the front of the pump.

Cummins Turbo (S/N 3617 & After) - The assem-
bly is bolted to the backside of the injector pump
and connected to a mechanical linkage.

MA6200

Fig. 10.20 Fuel Run Solenoid

CUMMINS - TURBO

(S/N 3616 & BEFORE)

BOSCH INJECTOR PUMP

CUMMINS -

NATURALLY

ASPIRATED

ENGINES

LUCAS

INJECTOR

PUMP

CUMMINS -

TURBO (S/N 3617

& AFTER)

BOSCH

INJECTOR PUMP

PERKINS

ENGINES ONLY

1

2

1

2

1

2

LOCATED

BEHIND FUEL

INJECTOR

PUMP