SkyTrak 6036 Service Manual User Manual
Page 268
![background image](/manuals/546105/268/background.png)
Section 10.
Electrical System
10-6
Model 6036/6036T S/N 9B0500 thru 14833
3
4
6
1
5
2
1. Circuit breaker, 6 A, protects steering select
valve circuit
2. Circuit breaker, 10 A, protects horn and backup
alarm (and optional cab heater fan) circuit
3. Circuit breaker, 6 A, protects instrument panel,
park lock solenoid switch
4. Circuit breaker, 40 A, protects ignition system
feed for entire electrical system
5. Circuit breaker, 6 A, protects enclosed cab
windshield washer/wiper and circulation fan
circuits (this breaker is optional and will not be
found on forklifts with an open cab)
6. Circuit breaker, 15 A, protects the optional
lighting package
OA0482
Fig. 10.5 Circuit Breakers
a.
Removal of Individual Circuit Breaker and
Circuit Breaker Bracket
1.
Disconnect negative (–) cable (2, Fig. 10.16)
from batteries.
2.
Tag and disconnect wiring from circuit breaker
by removing hex nuts and lock washers.
3.
Each circuit breaker is held in the circuit
breaker bracket by spring tension only.
Remove circuit breaker by inserting small slot
screwdriver between circuit breaker bracket
and left edge of circuit breaker and tilt breaker
out of bracket.
4
Disconnect wiring from all of the circuit
breakers in the bracket.
5.
Remove two nuts, lock washers and two
washers and slide bracket over the studs.
b. Installation of Circuit Breaker Bracket and
Individual Circuit Breaker
1.
Slide circuit breaker bracket over two studs
and secure using two washers, lock washers
and hex nuts.
2.
Position the terminal marked “BAT” on the
circuit breaker terminal plate to your right and
snap each circuit breaker into bracket using a
small slot screwdriver.
3.
Secure tagged wiring to respective terminals
using lock washers and hex nuts.
4.
Connect battery ground cable to the battery.
5.