Query errors – Agilent Technologies Agilent E5250A User Manual
Page 313

Agilent E5250A User’s Guide, Edition 11
11-9
Error Messages
Standard SCPI Error Messages
Query Errors
If the output queue control of the E5250A detects one of following problems, a
-4XX error occurs:.
•
An attempt was made to read data from the output queue when no output data is
present or pending.
•
Data in the output queue has been lost.
If this type of error occurs, the error number and message are placed in the error
queue, and bit2 of the Standard Event Status Register is set.
Error
Number
Error Message and Description
-400
Query error
Generic query error for the E5250A that cannot be determined more
specifically.
-410
Query INTERRUPTED
A condition causing an INTERRUPTED query error occurred; for
example, a query followed by DAB or GET before a response was
completely sent.
-420
Query UNTERMINATED
A condition causing an UNTERMINATED query error occurred; for
example, the E5250A was addressed to talk and an incomplete
program message was received.
-430
Query DEADLOCKED
A condition causing a DEADLOCKED query error occurred; for
example, both input buffer and output buffer are full and the E5250A
cannot continue.
-440
Query UNTERMINATED after indefinite response
A query was received in the same program message after a query
requesting an indefinite length response was executed.