:DIAGnostic:TEST:CARD:STATe?
:DIAGnostic:TEST:CARD:STATe?
This command returns the most recent relay test result for the specified card.
Syntax
:DIAGnostic:TEST:CARD:STATe? card_number
Query response
test_result
1 : Fail
0 : Pass
-1 : Not Tested
Example
OUTPUT @Hp5250;":DIAG:TEST:CARD:STAT? 1"
ENTER @Hp5250;A
:DIAGnostic:TEST:FRAMe:CLEar
This command clears test result of the specified E5250A test.
Syntax
:DIAGnostic:TEST:FRAMe:CLEar CONTroller | FPANel
Example
OUTPUT @Hp5250;":DIAG:TEST:FRAM:CLE CONT"
Parameter Explanation
card_number
card number: 1, 2, 3, 4
Parameter Explanation
CONTroller
Controller test
FPANel
Front panel interface test