beautypg.com

3 [settings] [homing paramet, Settings] [homing paramet – Festo Контроллеры двигателя SFC-LAC User Manual

Page 91

background image

4. Control panel (only type SFC−LACI−...−H2)

4−15

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

4.5.3

[Settings] [Homing paramet.]

Setting the homing method and the speed during reference
travel.

·

Observe the instructions in section 5.2.1.

[Hom. paramet.]

Param.

Description

[Homing method]

switch negative

Homing to the integrated
reference switch at the
retracted end position with
index search

block negative

Homing to a negative
fixedĂstop

block positive

Homing to positive
fixedĂstop

Note:
Further homing run methods can only be
configured via FCT.

[Velocity v_rp]

v_rp

Speed for searching for the
reference point

[Velocity v_zp]

v_zp

Speed for moving to the
axis zero point

[SAVE...]

Save parameters in EEPROM

Note
A new homing run must always be carried out after
modifying the homing run method.

The maximum speed for homing is subject to built−in limits.