6. Diagnosis and fault display

6−15

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

6.5

Diagnosis via PROFIBUS−DP

The SFC−LACI supports the following diagnostic possibilities
via PROFIBUS−DP:

ć

FHPP Status−Bytes (see section 5.6.2):
ć SCON.B2 WARN ć Warning
ć SCON.B3 FAULT ć Error
ć SPOS.B5 DEV

ć Drag error

ć SPOS.B6 STILL ć Standstill monitoring

ć

Diagnosing the PROFIBUS−DP :
PROFIBUS service 

GetDiag" with device−related

diagnosis (GbD) when activated.

The alarm model as per DPV1 is not supported.

Structure of the DP diagnosis (GetDiag)

The SFC−LACI supports Device−related" diagnosis of the
GetDiag" PROFIBUS service, as per IEC 61158−6 Type 3.

Note
The Identifier−related" or Channel−related" diagnosis
listed in IEC 61158−6 type 3 is not supported.

The method used for requesting a slave diagnosis can be
found in the manual for the DP master.