5. Commissioning
5−11
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Setting parameters
1. Set the following:
ć
Homing method [Homing method]
ć
Search speed for ascertaining the reference point
[Velocity v_rp]
ć
Speed of travel to axis zero point [Velocity v_zp].
2. Accept each setting with OK
The setting will then take effect in the drive.
3. Save the parameter settings in EEPROM with the
[SAVE]
menu command. Only then will the settings be retained if
the power supply is switched off or if there is a power
failure.
5.2.2
Activate device control
·
Enable the control panel so that it can control the
SFC−LACI [HMIĂ=Ăon]. This deactivates at the same time
the controller interface of the SFC−LACI.
Caution
When control via the control panel or FCT is activated
(HMI:on), the drive
cannot be stopped with the STOP bit of
the control interface.
Commutation point search:
When the controller is enabled for the first time with the
ENABLE signal or [HMIĂ=Ăon], the drive will spend a few
seconds determining its commutation point (vibrations).
} Settings
Homing paramet.
Homing method
Velocity v_rp
Velocity v_zp
SAVE...
Diagnostic
Positioning
Settings
}
HMI control
LCD adjustment
PLEASE WAIT
COMMUT.–POINT
EVALUATION IS
ACTIVE.