Record Table Element

CI

20E0h

01h ... 0Bh

Record

Various

rw

Description

Editing the entries in the positioning record table:
1. Selection of line with object 2032h (record pointer)
2. Select column under subindex 20E0: 01 ... 0Bh

20E0/01

20E0/02
V

20E0/03

20E0/04

20E0/05

20E0/...

Record
number

RCW

Target
position

Velocity

AccelerĆ
ation

Jerk

...

02

2032h

}

03

<1>

<...>

...

The values are only saved in the position record table with this command;
no movement is made.

Record Control

Word

20E0h

01h

uint16

Word

(RCW) Record control word (SSW) Matches 20EAh and 20EBh.

Bit 0:

= 0 absolute position specification
= 1 relative position specification

Bit 1 ... 2:

both = 0 standard path generator
both = 1 energy optimised path generator

Bit 3 ... 7:

not used (= 0)

Bit 8:

= 0 no further record switching
= 1 further record switching

Bit 9 ... 14: not used (= 0)
Bit 15:

= 0 record chaining is not locked out
= 1 record chaining is locked out

Note:
The energy optimised path generator enables higher dynamics with less heat,
the parametrised positioning curve (a trapeze) is not maintained exactly.
The parametrised maximum values for speed and acceleration may be slightly
exceeded.

Target Position 20E0h

02h

int32

Target position in [Increments] (matches 607Ah and 20ECh)

Velocity

(speed)

20E0h

03h

int32

(speed)

Speed in [Increments/s] (matches 6081h und 20EDh)