B. Supplementary information

B−61

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

Force mode

Stroke Limit

PNU

510

ć

ć

uint32

rw

Description

Stroke limitation: Maximum permitted stroke with force control. The distance of
the actual position from the start position must not be more than the amount
specified in this parameter. In this way you can ensure that, if force control is
activated by mistake (e.g. missing work item), the axis will not perform an unĆ
controlled movement. This parameter is taken into account in all control modes
in which the position controller is not active in the status Operation enabled".
Monitoring can be deactivated when bit RCB1.B5 is set.

CI

60F6h

0

1h

uint32

rw

Min. Torque/Force

PNU

511

ć

ć

uint16

r

Description

The lowest permitted torque of the motor in per mill of the rated value
(6076h / PNUĂ1036). Fixed = 300

CI

60F6h

0

5h

uint16

r

Max. Torque/Force

PNU

512

ć

ć

uint16

rw

Description

The highest permitted torque of the motor in per mill of the rated value
(6076h / PNUĂ1036). Values: 0 ... 1000

CI

6072h

00h

uint16

rw

Torque/Force Profile Type

PNU

513

ć

int16

r

Description

Type of profile with which a force modification is undertaken.
Fixed = 0: linear ramp

CI

6088h

00h

int16

r