Force mode – Festo Контроллеры двигателя SFC-LAC User Manual
Page 281

B. Supplementary information
B−61
Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH
Force mode
Stroke Limit
PNU
510
ć
ć
uint32
rw
Description
Stroke limitation: Maximum permitted stroke with force control. The distance of
the actual position from the start position must not be more than the amount
specified in this parameter. In this way you can ensure that, if force control is
activated by mistake (e.g. missing work item), the axis will not perform an unĆ
controlled movement. This parameter is taken into account in all control modes
in which the position controller is not active in the status Operation enabled".
Monitoring can be deactivated when bit RCB1.B5 is set.
CI
60F6h
0
1h
uint32
rw
Min. Torque/Force
PNU
511
ć
ć
uint16
r
Description
The lowest permitted torque of the motor in per mill of the rated value
(6076h / PNUĂ1036). Fixed = 300
CI
60F6h
0
5h
uint16
r
Max. Torque/Force
PNU
512
ć
ć
uint16
rw
Description
The highest permitted torque of the motor in per mill of the rated value
(6076h / PNUĂ1036). Values: 0 ... 1000
CI
6072h
00h
uint16
rw
Torque/Force Profile Type
PNU
513
ć
int16
r
Description
Type of profile with which a force modification is undertaken.
Fixed = 0: linear ramp
CI
6088h
00h
int16