Objects of the standstill monitoring

Position Demand Value

PNU

1040

ć

ć

int32

r

Description

Controller setpoint position in [Increments]

CI

6062h

00h

int32

r

Position Actual Value

PNU

1041

ć

ć

int32

r

Description

Current position of the drive in [Increments]

CI

6064h

00h

int32

r

Standstill Position Window

PNU

1042

ć

ć

uint32

rw

Description

Standstill position window in [Increments]ā: Amount by which the drive may
move after Motion Complete", until the standstill monitoring responds.

CI

2040h

00h

uint32

rw

Standstill Timeout

PNU

1043

ć

ć

uint16

rw

Description

Standstill monitoring time in [ms}: Time during which the drive must be outside
the standstill position window before the standstill monitoring responds.
Value range: 0 ... 65535 (0xFFFF). Default: 80

CI

2041h

00h

uint16

rw