B. Supplementary information

B−43

Festo P.BE−GDCP−SFC−LACI−PB−E N en 0812NH

FHPP Control Data

PNU

321

1 ... 2

Record

uint32

r

Description

FHPP output data (8 bytes of status date), 4 bytes each, consistent

1

FHPP control bytes 1 ... 4 (CCON, CPOS, ...)

2

FHPP control bytes 5 ... 8 (setpoint position)

CI

20A1h

01h ... 02h

uint32

r

Control Word

PNU

330

ć

uint16

rw

Description

Control word: Modify the current controller status or trigger an activity.
As status modifications require a certain amount of time, all status modificaĆ
tions triggered via the control word must be read back via the status word
(6041h). Further commands cannot be written via the control word until the
requested status can be read in the status word.
Typical values: see Tab. B/9
Bit assignment: see Tab. B/10

CI

6040h

00h

uint16

rw

Value

Function

0x000F

ENABLE OPERATION, Controller enable

0x000D

VOLTAGE DISABLE, end stage off

0x001F

Start ABSOLUTE movement

0x005F

Start RELATIVE movement

0x010F

Stop movement

0x008F

Reset error + ENABLE OPERATION

0x004F

Set target position as RELATIVE

Tab. B/9:

Typical values control word