Load-sharing example, Load-sharing example -8, Table 3-5 – Allied Telesis AT-8550 User Manual
Page 62

Load Sharing on the Switch
3-8
To define a load-sharing group, you assign a group of ports to a
single, logical port number. To enable or disable a load-sharing
group, use the following commands:
enable sharing
disable sharing
Load-Sharing
Example
The following example defines a load-sharing group that contains
ports 9 through 12, and uses the first port in the group as the master
logical port 9:
enable sharing 9 grouping 9-12
In this example, logical port 9 represents physical ports 9 through 12.
When using load sharing, you should always reference the master
logical port of the load-sharing group (port 9 in the previous
example) when configuring or viewing VLANs. VLANs configured to
use other ports in the load-sharing group will have those ports
deleted from the VLAN when load sharing becomes enabled.
Table 3-5 Port Combinations for the AT-8550
Load-Sharing Group
1 2 3 4 5 6 7 8 9
1
0
1
1
1
2
1
3
1
4
1
5
1
6
1
7
1
8
1
9
2
0
2
1
2
2
2
3
2
4
4-port groups
x x x x x x x x x x x x x x x x x x x x x x x x
2-port groups
x x x x x x x x x x x x x x x x x x x x x x x x
Load-Sharing Group 2
5
2
6
2
7
2
8
2
9
3
0
3
1
3
2
3
3
3
4
3
5
3
6
3
7
3
8
3
9
4
0
4
1
4
2
4
3
4
4
4
5
4
6
4
7
4
8
4-port groups
x x x x x x x x x x x x x x x x x x x x x x x x
2-port groups
x x x x x x x x x x x x x x x x x x x x x x x x
Load-Sharing Group 4
9
5
0
4-port groups
2-port groups
x x