Allied Telesis AT-8550 User Manual
Page 222

Status Monitoring
13-2
describes
show
commands that are used to monitor the
status of the switch.
Table 13-1 Status Monitoring Commands
Command
Description
show diag
Displays software diagnostics.
show log {
Displays the current snapshot of the log. Options include:
❑
priority
— Filters the log to display message with the
selected priority or higher (more critical). Priorities
include critical, emergency, alert, error, warning, notice,
info, and debug. If not specified, informational priority
messages and higher are displayed.
show log config
Displays the log configuration, including the syslog host IP
address, the priority level of messages being logged locally,
and the priority level of messages being sent to the syslog
host.
show memory
Displays the current system memory information.
show switch
Displays the current switch information, including:
❑ sysName, sysLocation, sysContact
❑ MAC address
❑ Current time and time, and system uptime
❑ Operating environment (temperature, fans, and power
supply status)
❑ NVRAM image information (primary/secondary image,
date, time, size, version)
❑ NVRAM configuration information (primary/secondary
configuration, date, time, size, version)
❑ Scheduled reboot information
❑ 802.1p information
❑ System serial number and reworks indicator
❑ Software platform
❑ System ID
❑ Power supply and fan status
show version
Displays the hardware and software versions currently
running on the switch. Displays the switch serial number.