Chapter 5: Monitoring System Performance

54

Using the System Activity Monitor

The AT-S70 management software keeps a list of the chassis SNMP
events such as removal of a line card, loss of a data link, failure of a fan
module, etc. This list is called the activity log and you use the activity
monitor to display the log. The activity log contains only those events that
have occurred since you started the management session. Ending the
session purges the log.

SNMP Traps

The SNMP traps provide information for status of chassis modules such
as line cards, fans, power supplies, as well as chassis temperature.

Activities that generate the SNMP traps are listed as follows:

ˆ

Module inserted

ˆ

Module removed

ˆ

Port link online

ˆ

Port link offline

ˆ

Fan failure - fan one of tray one

ˆ

Fan failure - fan two of tray one

ˆ

Fan failure - fan one of tray two

ˆ

Fan failure - fan two of tray two

ˆ

Fan recovered - fan one of tray one

ˆ

Fan recovered - fan two of tray one

ˆ

Fan recovered - fan one of tray two

ˆ

Fan recovered - fan two of tray two

ˆ

12V power failure

ˆ

5V power failure

ˆ

3.3V power failure

ˆ

12V power recovered

ˆ

5V power recovered

ˆ

3.3V power recovered

ˆ

Power supply module inserted

ˆ

Power supply module removed

ˆ

Chassis Over-Temperature

ˆ

Chassis Over-Temperature removed

ˆ

Fan module inserted

ˆ

Fan module removed