Figure 37: devconfig settings editor – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 99

Section 7. Installation
99
Datalogger Sub-Tab
• Serial Number displays the CR800 serial number. This setting is set at the
factory and cannot be edited.
• OS Version displays the operating system version that is in the CR800.
• Station Name displays the name that is set for this station. The default
station name is the CR800 serial number.
• PakBus® Address allows users to set the PakBus® address of the
datalogger. The allowable range is between 1 and 4094. Each PakBus®
device should have a unique PakBus® address. Addresses >3999 force other
PakBus® devices to respond regardless of their respective PakBus® settings.
See the PakBus® Networking Guide (available from Campbell Scientific) for
more information.
• Security - See Security
(p. 70).
ComPorts Settings Sub-Tab
As shown in figure DevConfig Deployment | ComPorts Settings Tab
(p. 100),
the
following settings are available for comports.
Read More! PakBus
®
Networking Guide available at www.campbellsci.com.
• Selected Port specifies the datalogger serial port to which the beacon interval
and hello-setting values are applied.
• Beacon Interval sets the interval (in seconds) on which the datalogger will
broadcast beacon messages on the port specified by Selected Port.
• Verify Interval specifies the interval (in seconds) at which the datalogger
will expect to have received packets from neighbors on the port specified by
Selected Port. A value of zero with automatically result in one of two
outcomes:
o a five-minute verify interval if the neighbor also has 0 set as the Verify
Interval argument, or
o the verify interval of the neighbor will be adopted if it is non-zero.
• Neighbors List, or perhaps more appropriately thought of as the "allowed
neighbors list", displays the list of addresses that this datalogger expects to
find as neighbors on the port specified by Selected Port. As items are selected
in this list, the values of the Begin and End range controls will change to
reflect the selected range. Multiple lists of neighbors can be added on the
same port.
• Begin and End Range are used to enter a range of addresses that can either
be added to or removed from the neighbors list for the port specified by
Selected Port. As users manipulate these controls, the Add- and Remove-
range buttons are enabled or disabled depending on the relative values in the
controls and whether the range is present in or overlaps with the list of
address ranges already set up.
• Add Range will cause the range specified in the Begin and End range to be
added to the list of neighbors to the datalogger on the port specified by