Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 508

Appendix B. Status Table and Settings
508
Table 117. Status-Table Fields and Descriptions
Fieldname Description
Variable
Type
Default
Range
Edit?
Info
Type
Low12VCount5
Number of times system
voltage dropped below 9.6
between resets. When this
condition is detected, the
CR800 ceases measurements
and goes into a low-power
mode until proper system
voltage is restored.
Integer 0
0-99
Yes
Reset by
changing to 0
Error
Low5VCount
Number of occurrences of
the 5V supply dropping
below a functional threshold.
Integer 0
0-99
Yes
Reset by
changing to 0
Error
CompileResults
Contains error messages
generated by compilation or
during runtime.
String
0
Error
StartUpCode6
A flag indicating that the
currently running program
was compiled due to a
power-up reset.
Integer
0
0 or 1
Status / Error
ProgErrors
The number of compile or
runtime errors for the current
program.
Integer
0
Error
VarOutOfBound7
Number of times an array
was accessed out of bounds.
Integer 0
0
Yes
Reset by
changing to 0
Error
SkippedScan
Number of skipped scans that
have occurred while running
the current program instance.
Does not include scans
intentionally skipped as may
occur with the use of
ExitScan and Do / Loop
instructions.
Integer 0
Yes
Reset by
changing to 0
Error
SkippedSystemScan8
The number of scans skipped
in the background
calibration.
Integer array
0
Yes
Reset by
changing to 0
Error
SkippedSlowScan9
The number of scans skipped
in a SlowSequence.
Integer array.
0
Yes
Reset by
changing to 0
Error
ErrorCalib8
The number of erroneous
calibration values measured.
The erroneous value is
discarded (not included in the
filter update).
Integer 0
0
Error
MemorySize
Total amount of SRAM
(bytes) in this device.
2097152 (2M)
4194304 (4M)
Status