Appendix B. Status Table and Settings
508
Table 117. Status-Table Fields and Descriptions
Fieldname Description
Variable
Type
Default
Range
Edit?
Info
Type
Low12VCount5
Number of times system 
voltage dropped below 9.6 
between resets. When this 
condition is detected, the 
CR800 ceases measurements 
and goes into a low-power 
mode until proper system 
voltage is restored. 
Integer 0
0-99
Yes 
Reset by 
changing to 0 
Error
Low5VCount
Number of occurrences of 
the 5V supply dropping 
below a functional threshold. 
Integer 0
0-99
Yes 
Reset by 
changing to 0 
Error
CompileResults
Contains error messages 
generated by compilation or 
during runtime. 
String
0
Error
StartUpCode6
A flag indicating that the 
currently running program 
was compiled due to a 
power-up reset. 
Integer
0
0 or 1
Status / Error
ProgErrors
The number of compile or 
runtime errors for the current 
program. 
Integer
0
Error
VarOutOfBound7 
 
Number of times an array 
was accessed out of bounds. 
Integer 0
0
Yes 
Reset by 
changing to 0 
Error
SkippedScan
Number of skipped scans that 
have occurred while running 
the current program instance. 
Does not include scans 
intentionally skipped as may 
occur with the use of 
ExitScan and Do / Loop 
instructions. 
Integer 0
Yes 
Reset by 
changing to 0 
Error
SkippedSystemScan8 
 
The number of scans skipped 
in the background 
calibration. 
Integer array
0
Yes 
Reset by 
changing to 0 
Error
SkippedSlowScan9
The number of scans skipped 
in a SlowSequence. 
Integer array.
0
Yes 
Reset by 
changing to 0 
Error
ErrorCalib8
The number of erroneous 
calibration values measured. 
The erroneous value is 
discarded (not included in the 
filter update). 
Integer 0
0
Error
MemorySize
Total amount of SRAM 
(bytes) in this device. 
2097152 (2M) 
4194304 (4M) 
Status