CRBasic Example 69. Using Bit‐Shift Operators 

Dim

input_val

As Long

Dim

value_1

As Long

Dim

value_2

As Long

Dim

value_3

As Long

'read input_val somehow

value_1 = (input_val AND &B11000000) >> 6
value_2 = (input_val AND &B00110000) >> 4

'note that value_3 does not need to be shifted

value_3 = (input_val AND &B00001111)

 

A.6.5 Logical Operators

AND 
Performs a logical conjunction on two expressions. 

Syntax 

result = expr1 AND expr2

EQV 
Performs a logical equivalence on two expressions. 

Syntax 

result = expr1 EQV expr2

NOT 
Performs a logical negation on an expression. 

Syntax 

result = NOT expression

OR 
Performs a logical disjunction on two expressions. 

Syntax 

result = expr1 OR expr2

XOR  
Performs a logical exclusion on two expressions. 

Syntax 

result = expr1 XOR expr2

IIF 
Evaluates a variable or expression and returns one of two results based on the 
outcome of that evaluation. 

Syntax 

Result = IIF (Expression, TrueValue, FalseValue)

IMP 
Performs a logical implication on two expressions. 

Syntax 

result = expression1 IMP expression2