Section 7. Installation

252 

 

 

'Begin Program

BeginProg

'Load scaling array (multipliers and offsets)

Mult(1) = 1.8 : Offset(1) = 32
Mult(2) = 1 : Offset(2) = 2
Mult(3) = 1 : Offset(3) = 3
Mult(4) = 1 : Offset(4) = 4
Mult(5) = 1 : Offset(5) = 5
Mult(6) = 1 : Offset(6) = 6
Mult(7) = 1 : Offset(7) = 7
Mult(8) = 1 : Offset(8) = 8
Mult(9) = 1 : Offset(9) = 9
Mult(10) = 1 : Offset(10) = 10

Scan

(5,Sec,1,0)

'Measure reference temperature

PanelTemp

(PTemp_C,_60Hz)

'Measure 5 thermocouples on CR1000

'Note: because of the use of repetitions, an array can be used for the

'destination, multiplier and offset.

TCDiff

(Temp_C(),5,mV2_5C,1,TypeT,PTemp_C,True ,0,250,Mult(),Offset())

'Measure 5 thermocouples on an AM16/32 Multiplexer (2x32 mode)

PortSet

(1,1)

Count = 6

'Start with 6 since scaling arrays 1 – 5

'already used

SubScan

(0,uSec,5)

PulsePort

(2,10000)

TCDiff

(Temp_C(Count),1,mV2_5C,6,TypeT,PTemp_C,True,0,_60Hz,Mult(Count),Offset(Count))

Count = Count + 1

NextSubScan

PortSet

(1,0)

CallTable

(min_5)

NextScan

EndProg

 

7.8.17.6 Conditional Output

CRBasic example Conditional Output

(p. 252)

demonstrates programming to output

data to a data table conditional on a trigger other than time.

CRBasic Example 57. Conditional Output 

'Programming example showing use of StationName instruction, use of units, and writing

'to a data table conditionally

'Declare Station Name (saved to Status table)

StationName

(Delta_Temp_Station)

'Declare Variables

Public

PTemp_C, AirTemp_C, DeltaT_C