Table 20. logical expression examples – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 149

Section 7. Installation
149
• Prc is the abbreviation of the name of the data process used. See table
Abbreviations of Names of Data Processes
(p. 149)
for a complete list of these
abbreviations. This is not needed for values from Status or Public tables.
• Fieldname Index is the array element number in fields that are arrays
(optional).
• Records Back is how far back into the table to go to get the value (optional).
If left blank, the most recent record is acquired.
Table 21. Abbreviations of Names of Data
Processes
Abbreviation Process
Name
Tot
Totalize
Avg
Average
Max
Maximum
Min
Minimum
SMM
Sample at Max or Min
Std
Standard Deviation
MMT
Moment
No abbreviation
Sample
Hst
Histogram
1
H4D
Histogram4D
FFT
FFT
Cov
Covariance
RFH
RainFlow Histogram
LCr
Level Crossing
WVc
WindVector
Med
Median
ETsz
ET
RSo
Solar Radiation (from ET)
TMx
Time of Max
TMn
Time of Min
1
Hst is reported in the form
Hst,20,1.0000e+00,0.0000e+00,1.0000e+01 where Hst denotes a
histogram, 20 = 20 bins, 1 = weighting factor, 0 = lower bound, 10 =
upper bound.
For instance, to access the number of watchdog errors, use the
status.watchdogerrors, where status is the table name, and watchdogerrors is
the field name.