A.5.10 Peripheral Device Support
Multiple SDM instructions can be used within a program.
AM25T
Controls the AM25T Multiplexer.
Syntax
AM25T(Dest, Reps, Range, AM25TChan, DiffChan, TCType, Tref,
ClkPort, ResPort, VxChan, RevDiff, SettlingTime, Integ,
Mult, Offset)
AVW200
Enables CR800 to get measurements from an AVW200 Vibrating Wire Spectrum
Analyzer.
Syntax
AVW200(Result, ComPort, NeighborAddr, PakBusAddr, Dest,
AVWChan, MuxChan, Reps, BeginFreq, EndFreq, ExVolt,
Therm50_60Hz, Multiplier, Offset)
CDM_VW300Config
Configures the CDM_VW300 Dynamic Vibrating Wire Module.
Syntax
CDM_VW300Config(DeviceType, CPIAddress, SysOptions,
ChanEnable, ResonAmp, LowFreq, HighFreq, ChanOptions,
Mult, Offset, SteinA, SteinB, SteinC, RF_MeanBins,
RF_AmpBins, RF_LowLim, RF_HighLim, RF_Hyst, RF_Form)
CDM_VW300Dynamic
Captures dynamic vibrating‐wire sensor readings from the CDM_VW300.
Syntax
CDM_VW300Dynamic(CPIAddress, DestFreq, DestDiag)
CDM_VW300Rainflow
Obtains rainflow histogram data from the CDM_VW300.
Syntax
CDM_VW300Rainflow(CPIAddress, RF1, RF2, RF3, RF4, RF5, RF6,
RF7, RF8)
CDM_VW300Static
Captures static vibrating‐wire sensor readings from the CDM_VW300.
Syntax
CDM_VW300Static(CPIAddress, DestFreq, DestTherm, DestStdDev)
CPISpeed
Controls the speed of the CPI bus.
Syntax
CPISpeed(BitRate))
MuxSelect
Selects the specified channel on a multiplexer.
Syntax
MuxSelect(ClkPort, ResPort, ClkPulseWidth, MuxChan, Mode)