4 glossary of terms – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual

Page 204

background image

Section 7. Installation

204 

 

 

addressing systems that allow multiplexing of several sensors on a single
communications port, which makes for more efficient use of resources.

7.8.8.4 Glossary of Terms

Asynchronous 

Indicates the sending and receiving devices are not synchronized using a 
clock signal. 

Baud rate 

The rate at which data are transmitted. 

Big Endian 

"Big end first." Placing the most significant integer at the beginning of a 
numeric word, reading left to right. 

cr 

Carriage return 

Data bits 

Number of bits used to describe the data, and fit between the start and 
stop bits. Sensors typically use 7 or 8 data bits. 

Duplex 

Can be half or full. Full‐duplex is simultaneous, bidirectional data. 

lf 

Line feed 

Little Endian 

"Little end first." Placing the most significant integer at the end of a 
numeric word, reading left to right. 

LSB 

Least significant bit (the trailing bit) 

Marks and Spaces 

RS‐232 signal levels are inverted logic compared to TTL. The different 
levels are called marks and spaces. When referenced to signal ground, 
the valid RS‐232 voltage level for a mark is ‐3 to ‐25, and for a space is