beautypg.com

Figure 38: summary of cr800 configuration, Figure 39: devconfig deployment tab – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual

Page 100

background image

Section 7. Installation

100 

 

 

Selected Port. This control is disabled if the end range value is less than the
begin range value.

Remove Range will remove the range specified by the values of the Begin

and End controls from the list of neighbors to the datalogger on the port
specified by Selected Port. This control is disabled if the range specified is
not present in the list.

• Help is displayed at the bottom of the Deployment tab. When finished,

Apply the settings to the datalogger. A summary message is presented. Save
or Print the settings to archive or to use as a template for another datalogger.

Cancel causes the datalogger to ignore the changes. Read File provides the

opportunity to load settings saved previously from this or another similar
datalogger. Changes loaded from a file will not be written to the datalogger
until Apply is clicked.

Figure 40: DevConfig Deployment | ComPorts Settings tab

Advanced Sub-Tab

Is Router allows the datalogger to act as a PakBus

®

router.

PakBus Nodes Allocation indicates the maximum number of PakBus

®

devices the CR800 will communicate with if it is set up as a router. This
setting is used to allocate memory in the CR800 to be used for its routing
table.

Max Packet Size is the size of PakBus

®

packets transmitted by the CR800.