376 

 

 

Table 98. FileControl API Command Parameters

action

1 — Compile and run the file specified by

file

and mark it as the program to be run on power up.

2 — Mark the file specified by

file

as the program to be run on power up.

3 — Mark the file specified by

file

as hidden.

4 — Delete the file specified by

file

.

5 — Format the device specified by

file

.

6 — Compile and run the file specified by

file

without deleting existing data tables.

7 — Stop the currently running program.
8 — Stop the currently running program and delete associated data tables.
9 — Perform a full memory reset.
10 — Compile and run the program specified by

file

but do not change the program currently

marked to run on power up.
11 — Pause execution of the currently running program.
12 — Resume execution of the currently paused program.
13 — Stop the currently running program, delete its associated data tables, run the program
specified by

file

, and mark the same file as the program to be run on power up.

14 — Stop the currently running program, delete its associated data tables, and run the program
specified by

file

without affecting the program to be run on power up.

15 — Move the file specified by

file2

to the name specified by file.

16 — Move the file specified by

file2

to the name specified by

file

, stop the currently running

program, delete its associated data tables, and run the program specified by

file2

while marking it

to run on power up.
17 — Move the file specified by

file2

to the name specified by

file

, stop the currently running

program, delete its associated data tables, and run the program specified by

file2

without affecting

the program that will run on power up.
18 — Copy the file specified by

file2

to the name specified by

file

.

19 — Copy the file specified by

file2

to the name specified by

file

, stop the currently running

program, delete its associated data tables, and run the program specified by

file2

while marking it

to run on power up.
20 — Copy the file specified by

file2

to the name specified by

file

, stop the currently running

program, delete its associated data tables, and run the program specified by

file2

without affecting

the program that will run on power up.

file

Specifies the first parameter for the file control operation. This parameter must be specified for

action

values

1, 2, 3, 4, 5, 6, 10, 13, 14, 15, 16, 17, 18, 19,

and

20

.

file2

Specifies the second parameter for the file control operation. This parameter must be specified for

action

values

15, 16, 17, 18, 19,

and

20

.

format

Specifies the format of the response. The values html, json, and xml are recognized. If this
parameter is omitted, or if the value is html, empty, or invalid, the response is HTML.

Example:

http://192.168.24.106/?command=FileControl&file=USR:APITest.dat&
action=4

Response: APITest.dat is deleted from the CR800 USR: drive. 

http://192.168.24.106/?command=FileControl&file=CPU:IndianaJones
_090712_2.CR1&action=1

Response: Set program file to Run Now. 

http://192.168.24.106/?command=FileControl&file=USR:FileCopy.dat
&file2=USR:FileName.dat&action=18

Response: Copy from file2 to file.