Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 511

Appendix B. Status Table and Settings
511
Table 117. Status-Table Fields and Descriptions
Fieldname Description
Variable
Type
Default
Range
Edit?
Info
Type
ProcessTime
Processing time (μs) of the
last scan. Time is measured
from the end of the EndScan
instruction (after the
measurement event is set) to
the beginning of the EndScan
(before the wait for the
measurement event begins)
for the subsequent scan.
Calculated dynamically (on
the fly).
Integer
Status
MaxProcTime
Maximum time (μs) required
to run through processing for
the current scan. This value
is reset when the scan exits.
Calculated dynamically (on
the fly).
Integer
Yes
Reset by
changing to 0
Status
BuffDepth
Shows the current Pipeline
Mode processing buffer
depth., which indicates how
far processing is currently
behind measurement.
MaxBuffDepth
Gives the maximum number
of buffers processing lagged
measurement.
LastSystemScan8
The last time the background
calibration executed.
Integer array
Status
LastSlowScan9
The last time SlowSequence
scan(s) executed.
Integer array
Status
SystemProcTime8,12
The time (μs) required to
process the background
calibration.
Integer array
Status
SlowProcTime9,12
The time (μs) required to
process SlowSequence
scan(s).
Integer array
Status
MaxSystemProcTime8,
13
The maximum time (μs)
required to process the
background calibration.
Integer array
Status
MaxSlowProcTime9,13
The maximum time (μs)
required to process
SlowSequence scan(s).
Integer array
Status
PortStatus
Array of Boolean values
posting the state of control
ports. Values updated every
500 ms.
Boolean array of 8
False
True or False
Yes
Status
PortConfig
Array of strings explaining
the use of the associated
control port. Valid entries
are: Input, Output, SDM,
SDI-12, Tx, and Rx.
String array of 8
Input
Input or Output
Status
SW12Volts
Status of switched, 12-Vdc
port
Boolean False
True
or
False
Yes
Status