Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 371

Section 8. Operation
371
ClockSet Response
The ClockSet
format
parameter determines the format of the response. If a format
is not specified, the format defaults to HTML. For more detail concerning data
response formats, see the Data File Formats
section.
Responses contain three fields as described in the following table:
Table 94. ClockSet API Command Response
outcome
1 — The clock was set
5 — Communication with the CR800 failed
6 — Communication with the CR800 is disabled
8 — An invalid URI was specified.
time
Specifies the value of the CR800 clock before it was changed.
description
A string that describes the outcome code.
HTML Response
When
html
is entered in the ClockSet
format
parameter, the response will be
HTML. Following are example responses.
HTML tabular response:
HTML page source:
"http://www.w3.org/TR/html4/loose.dtd">
ClockSet Response
outcome | 1 | time | 2011-12-01 11:42:02.75 |
description | The clock was set |
XML Response
When
xml
is entered in the ClockSet
format
parameter, the response will be
formated as CSIXML
(p. 68)
with a ClockSetResponse root element name.
Following is an example response.