A.16 information services, Crbasic example 69. using bit-shift operators – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual
Page 496

Appendix A. CRBasic Programming Instructions
496
TableName.Output
Determine if data was written to a specific data table the last time the data table
was called.
Syntax
TableName.Output(1,1)
TableName.Record
Determines the record number of a specific data table record.
Syntax
TableName.Record(1,n)
TableName.TableFull
Indicates whether a fill‐and‐stop table is full or whether a ring‐mode table has
begun overwriting its oldest data.
Syntax
TableName.TableFull(1,1)
TableName.TableSize
Returns the number of records allocated for a data table.
Syntax
TableName.TableSize(1,1)
TableName.TimeStamp
Returns the time into an interval or a time stamp for a record in a specific data
table.
Syntax
TableName.TimeStamp(m,n)
WorstCase
Saves one or more "worst case" data storage events into separate tables. Used in
conjunction with DataEvent().
Syntax
WorstCase(TableName, NumCases, MaxMin, Change, RankVar)
A.16 Information Services
These instructions address use of email, SMS, Web Pages, and other IP services.
These services are available only when the CR800 is used with network link-
devices that have the PPP/IP key enabled, i.e., when the CR800 IP stack is used.
See the appendix Network Links
(p. 545).
Read More! See Information Services
(p. 167).
DHCPRenew
Restarts DHCP on the ethernet interface.
Syntax
DHCPRenew