Section 10. Troubleshooting

422 

 

 

As shown in figure DevConfig Terminal Emulator

(p. 424),

after entering a terminal

emulator, press Enter a few times until the prompt CR800> is returned. Terminal
commands consist of a single character and Enter. Sending an H and Enter will
return the terminal emulator menu

(p. 422).

ESC or a 40-second timeout will terminate on-going commands. Concurrent
terminal sessions are not allowed.

Table 111. CR800 Terminal Commands

Option Description

Use

0

Scan processing time; real time in seconds

Lists technical data concerning program scans.

1

Serial FLASH data dump

Campbell Scientific engineering tool

2

Read clock chip

Lists binary data concerning the CR800 clock chip.

3

Status

Lists the CR800 Status table.

4

Card status and compile errors

Lists technical data concerning an installed CF card.

5

Scan information

Technical data regarding the CR800 scan.

6

Raw A/D values

Technical data regarding analog-to-digital conversions.

7

VARS Lists

Public table variables.

8

Suspend / start data output

Outputs all table data. This is not recommended as a
means to collect data, especially over
telecommunications. Data are dumped as non-error
checked ASCII.

9

Read inloc binary

Lists binary form of Public table.

A

Operating system copyright

Lists copyright notice and version of operating system.

B

Task sequencer op codes

Technical data regarding the task sequencer.

C

Modify constant table

Edit constants defined with ConstTable /
EndConstTable. Only active when ConstTable /
EndConstTable in the active program.

D

MTdbg() task monitor

Campbell Scientific engineering tool

E

Compile errors

Lists compile errors for the current program download
attempt.

F

VARS without names

Campbell Scientific engineering tool

G

CPU serial flash dump

Campbell Scientific engineering tool

H

Terminal emulator menu

Lists main menu.

I

Calibration data

Lists gains and offsets resulting from internal calibration
of analog measurement circuitry.

J

Download file dump

Sends text of current program including comments.

K

Unused

L

Peripheral bus read

Campbell Scientific engineering tool

M

Memory check

Lists memory-test results

N

File system information

Lists files in CR800 memory.

O

Data table sizes

Lists technical data concerning data-table sizes.

P

Serial talk through

Issue commands from keyboard that are passed through
the logger serial port to the connected device. Similar in