beautypg.com

3 loggernet setup, Figure 103: pakbus network addressing – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual

Page 344

background image

Section 8. Operation

344 

 

 

Table 82. PakBus-LAN Example Datalogger-Communications Settings

Software→

Device Configuration Utility (DevConfig)

Tab→

Deployment

Sub-Tab→

Datalogger

ComPort Settings

Advanced

Setting→

PakBus Adr

COM1

COM2

Is Router

Sub-Setting→

Baud Rate

Neighbors

1

Baud Rate

Neighbors

1

Datalogger ↓

Begin:

End:

Begin:

End:

CR800_1

1

115.2K Fixed

2

2

115.2K Fixed

3

4

Yes

CR800_2

2

115.2K Fixed

1

1

Disabled

No

CR800_3

3

115.2K Fixed

1

1

115.2K Fixed

4

4

Yes

CR800_4

4

115.2K Fixed

3

3

Disabled

No

1

Setup can be simplified by setting all neighbor lists to Begin: 1 End: 4.

 

8.5.6.3 LoggerNet Setup

Figure 110: LoggerNet Network-Map Setup: COM port

In LoggerNet Setup, click Add Root and add a ComPort. Then Add a
PakBusPort, and (4) CR800 dataloggers to the device map as shown in figure
LoggerNet Device-Map Setup

(p. 344).