beautypg.com

7 formatting strings, 8 formatting string hexadecimal variables, 14 data tables – Campbell Scientific CR800 and CR850 Measurement and Control Systems User Manual

Page 241: Table 36. measuring voltse() at 2000 hz

background image

Section 7. Installation

241

 

7.8.13.7 Formatting Strings

Table 43. Formatting Strings Examples

Expression Result

Str(1)=123e4
Str(2)=FormatFloat(123e4,"%12.2f")
Str(3)=FormatFloat(Values(2)," The battery is %.3g Volts ")
Str(4)=Strings(3,1,InStr(1,Strings(3),"The battery is ",4))
Str(5)=Strings(3,1,InStr(1,Strings(3),"is ",2) + 3)
Str(6)=Replace("The battery is 12.4 Volts"," is "," = ")
Str(7)=LTrim("The battery is 12.4 Volts")
Str(8)=RTrim("The battery is 12.4 Volts")
Str(9)=Trim("The battery is 12.4 Volts")
Str(10)=UpperCase("The battery is 12.4 Volts")
Str(12)=Left("The battery is 12.4 Volts",5)
Str(13)=Right("The battery is 12.4 Volts",7)

1230000
1230000.00
“The battery is 12.4 Volts”
12.4 Volts
12.4 Volts
The battery = 12.4 Volts
The battery is 12.4 Volts
The battery is 12.4 Volts
The battery is 12.4 Volts
THE BATTERY IS 12.4 VOLTS
The b
Volts

 

CRBasic Example 49. Formatting Strings 

Objective:
Format the string "The battery is 12.4 Volts"

Use CRBasic expression:
StringVar(11) =

Mid

("The battery is 12.4 Volts", _

InStr

(1,"The battery is 12.4 Volts"," is ",2)+3,

Len

("The battery is 12.4 Volts"))

Result:
12.4 Volts

 

7.8.13.8 Formatting String Hexadecimal Variables

Table 44. Formatting Hexadecimal Variables - Examples

Expression Comment

Result

CRLFNumeric(1) = &H0d0a

Add leading zero to hex step 1

3338

StringVar(20) = "0" & Hex(CRLFNumeric)

Add leading zero to hex step 2

0D0A

CRLFNumeric(2) = HexToDec(Strings(20))

Convert Hex string to Float

3338.00

 

7.8.14 Data Tables

CRBasic Example 50. Two Data Intervals in One Data Table 

'CRBasic program to write to a single table with two different time intervals.

'Note: this is a conditional table, check the table fill times in the Status table.

'For programs with conditional tables AND other time driven tables, it is generally

'wise to NOT auto allocate the conditional table; set a specific number of records.

'Declare Public Variables

Public

PTemp, batt_volt, airtempC, deltaT

Public

int_fast

As Boolean

Public

int_slow

As Boolean

Public

counter(4)

As Long