HP StorageWorks XP Remote Web Console Software User Manual
Page 37
Continuous Access XP Journal user guide
37
•
Primary data volume records updated by host-requested write I/Os after the pair was suspended
describes Continuous Access XP Journal suspension conditions and indicates which CU detects
the condition and which pairs are suspended. See ”
Displaying the History Operation pane
for troubleshooting information for Continuous Access XP Journal suspension conditions.
Table 8
Continuous Access XP Journal suspension conditions
Suspension condition
Detected by Continuous Access XP Journal pairs to be
suspended
The secondary array could not copy the journal
data successfully due to a hardware failure or
logic error.
RCU
All Continuous Access XP Journal secondary
data volumes in the journal groups, or the
affected secondary data volume
The secondary array detected a logical error
while selecting the journal data to be restored.
RCU
All Continuous Access XP Journal secondary
data volumes in the journal group, or only the
affected secondary volume
The secondary array could not restore the
journal data due to a hardware failure, track
condition, or logical error.
RCU
All Continuous Access XP Journal secondary
data volumes in the journal groups, or the
affected secondary data volume