beautypg.com

Starting and stopping usage monitoring, Starting usage monitoring, Stopping usage monitoring – HP StorageWorks XP Remote Web Console Software User Manual

Page 136: Displaying the usage monitor graph

background image

136 Monitoring remote copy operations

NOTE:

When monitoring is stopped, the usage monitor graph is closed. The usage monitor graph

only appears when monitoring is running.

Gathering Interval: Data collection interval for usage monitoring between 1 and 15 minutes in one

minute increment. The default is 1.

NOTE:

When monitoring is stopped, the default (1) appears in the Gathering Interval box.

Update: Displays the most recent data sample time on the graph.

Graph: Displays remote I/O statistic information and status of the remote copy monitor.

Apply: Applies settings in the Usage Monitor pane to the array.

Cancel: Cancels settings in the Usage Monitor pane.

Starting and stopping usage monitoring

At each data sampling time interval, the usage monitoring function collects 1,440 pieces of data for each

LDEV and up to 1,440 pieces of data for the entire array.

Starting usage monitoring

1.

Select the Usage Monitor tab.

2.

In the Monitoring Switch box, select Enable.

3.

Select the sampling time interval (in minutes) from the Gathering Interval list. If the desired value is not

in the list, enter the time interval directly. You can enter from 1 to 15 minutes. The default is 1 minute.

NOTE:

If you set 1 minute for Gathering Interval, the sampling data is held one day. If you set

15 minutes for Gathering Interval, the sampling data is held 15 days. When you change

Gathering Interval, data obtained before the change is deleted.

4.

Click Apply.

Stopping usage monitoring

1.

Select the Usage Monitor tab.

2.

In the Monitoring Switch box, select Disable.

3.

Click Apply.

NOTE:

Depending on the SVP’s load status, you might not be able to stop monitoring. If you cannot stop

monitoring immediately, wait for a while, and click Refresh (

) (top right of Command View XP or XP

Remote Web Console pane) to check the status of the monitor.

NOTE:

Monitoring data collection continues, even if the pane is closed, until you stop monitoring

operations. Monitoring data collection continues even if the SVP is rebooted.

Displaying the usage monitor graph

When usage monitoring is running, the Usage Monitor pane displays user-selected remote copy I/O

statistics in real time. I/O statistics data is collected according to the data-sampling rate selected in the

Gathering Interval box.
The usage monitor graph plots user-selected I/O statistics (up to 65 data points) on an x-y graph. The

x-axis displays time. The y-axis displays the number of I/Os during the last sampling period. The legend

(right side of the graph) indicates data being displayed. A value on the y-axis varies according to the