NOTE:

If Range is Group, you cannot change Priority.

DKC: Array.

Resync Mode: Processing after recovery of the pairs.
• Normal: A split pair whose status is PSUS or PSUE is recovered.
• Return to standby: The pair status is recovered from HLDE to HOLD.

Error Level: Range used for splitting a pair when a failure occurs.
• Group: If a failure occurs with a pair, all pairs in the consistency group where the pair belongs are

split.

• LU: If a failure occurs with a pair, only the pair is split.

NOTE:

If Range is Group, you cannot change Error Level.

Set: Applies settings to the Preset list in the Pair Operation pane.

Cancel: Discards settings.

Deleting a pair of data volumes

Use the Pairsplit-S pane (

Figure 59

) to delete a pair of data volumes.

To delete one or more pairs, the primary and secondary array administrator can use the following

procedure:

1.

Ensure that Command View XP or XP Remote Web Console is in Modify mode. For more information,

see the HP StorageWorks Command View XP user guide for XP Disk Arrays or the HP StorageWorks XP

Remote Web Console user guide for XP12000/XP10000/SVS200.

2.

Display the Pair Operation pane (see

Displaying the Pair Operation pane

” on page 115).

3.

In the tree, select Subsystem or a port ( ).

4.

In the list, right-click the pair you want to delete.

5.

Select Pairsplit-S. The Pairsplit-S pane (

Figure 59

) appears.

6.

Select the options for the pairs.

7.

Click Set.

8.

In the Preset list on the Pair Operation pane, check the settings you made.
• To modify a setting, right-click the setting, and select Modify.
• To cancel a setting, right-click the setting, and select Cancel.

9.

Click Apply to restore pairs.

NOTE:

If an error occurs, the right-most column of the Preset list displays the error code. To view

detailed information about the error, right-click the error code, and select Error Detail. An error

message appears providing detailed information about the error.

10.

In the list on the Pair Operations pane, verify that the pairs were successfully deleted. If the pair was

deleted, the status of the pair is SMPL.
To monitor the progress of deleting pairs, click Refresh to update the information in the list, or use the

Pairdisplay pane (see ”

Displaying detailed information about a pair of data volumes

” on page 125)

to monitor the detailed status of each pair.

NOTE:

To restore a pair that was deleted from the secondary array, delete the pair from the primary

array, and restore the pair using the appropriate initial copy option.