beautypg.com

Table 7 suspend types (psue), Continuous access xp journal suspension conditions, 7 suspend types (psue) – HP StorageWorks XP Remote Web Console Software User Manual

Page 36: Table 7 on, N (see, Continuous, Access xp journal suspension conditions” on, Table 7

background image

36

Overview of Continuous Access XP Journal

is suspended. Primary and secondary arrays also keep track of any journal data discarded during the

pair suspension. When the suspended Continuous Access XP Journal pair is resumed (pairresync), the

secondary array sends the secondary data volume’s bitmap to the primary array, and the primary array

merges the primary and secondary data volumes’ bitmaps to determine which cylinders/tracks are

out-of-sync. The primary array merges the primary and secondary data volumes’ bitmaps to identify

out-of-sync cylinders/tracks. This method ensures that all cylinders/tracks containing journal data

discarded at the secondary array are resynchronized at this time.
A split (or suspended) Continuous Access XP Journal secondary data volume has an additional status

called the consistency status. The consistency status is displayed only at the secondary array and indicates

the update sequence consistency of the secondary data volume with respect to the other secondary data

volume in the same group.

Table 6

describes consistency statuses for split or suspended Continuous

Access XP Journal secondary data volumes (the consistency status is displayed only at the secondary

array).

Continuous Access XP Journal suspension conditions

Continuous Access XP Journal operations involve additional suspension conditions related to

asynchronous journal operations. The primary and secondary arrays can detect Continuous Access XP

Journal suspension conditions and suspend Continuous Access XP Journal pairs. The primary array stores

a differential bitmap per Continuous Access XP Journal primary data volume in shared memory. The

secondary array stores a differential bitmap per Continuous Access XP Journal secondary data volume in

shared memory. When a Continuous Access XP Journal pair is suspended, tracks containing the following

journal are marked in the differential bitmap as modified (to be copied during the pairresync operation):

Journal data the primary array has created, but has not sent to the secondary array yet
After marking these primary data volume tracks as modified, the primary array discards the journal

data.

Journal data that has been sent to the secondary array, but has not been acknowledged by the

secondary array
After marking these primary data volume tracks as modified, the primary array discards the journal

data. This ensures that journal data lost during transmission to the secondary array is identified and

marked.

Journal data that has reached the secondary array, but has not been restored yet
After marking these primary data volume tracks as modified, the primary array discards the journal

data. Therefore, the secondary array can check and mark journal data that has not been restored.
The primary array does not discard journal data from the master journal volume until the primary

array receives the restored journal volumes’ sequence numbers, which are included in read journal

commands from the secondary array.

Table 7

Suspend types (PSUE)

Type

Applies to

Description

PSUE, S-VOL Failure

Primary data volume,

Secondary data volume

The primary array detected an error during

secondary array communications or during update

copy. In this case, the secondary data volume

suspend type is usually PSUE-S-VOL Failure.

PSUE, MCU IMPL

Primary data volume,

Secondary data volume

The primary array could not find valid control

information in its nonvolatile memory during IMPL.

This condition occurs only if the primary array is

without power for more than 48 hours (for example,

a power failure and fully discharged backup

batteries).

PSUE Initial Copy Failed

Primary data volume,

Secondary data volume

The Continuous Access XP Journal pair was

suspended before the initial copy operation

completed. Data on the secondary data volume is not

identical to data on the primary data volume.

PSUE, MCU P/S OFF

Secondary data volume

The primary array is powered off.