beautypg.com

Table 35 – HP StorageWorks XP Remote Web Console Software User Manual

Page 183

background image

Continuous Access XP Journal user guide 183

Table 35

Troubleshooting suspended Continuous Access XP Journal pairs

Suspend

type

Applies to

Description

Corrective action

PSUE, by

RCU

Primary data

volume

Primary array suspended a pair

because the primary array detected an

error condition at the secondary array.

The suspend type for the secondary

data volume is by MCU.

Clear the error condition at the

secondary array or secondary data

volume. To access the secondary data

volume, delete the pair from the

primary array. If data in the secondary

data volume has been changed,

delete the pair from the primary array,

and recreate the pair using the

Paircreate pane. If data in the

secondary data volume has not been

changed, restore the pair from the

primary array.

PSUE,

S-VOL

Failure

Primary data

volume

Primary array detected an error during

communication with the secondary

array or detected an I/O error during

update copy. In this case, the suspend

type for the secondary data volume is

usually by MCU.

Check the path status on the DKC

Status pane (see

Table 34

).

Clear any error conditions at the

secondary array and secondary data

volume. To access the secondary data

volume, delete the pair from the

secondary array. If data in the

secondary data volume has been

changed, delete the pair from the

primary array, and re-create the pair

using the Paircreate pane. If data in

the secondary data volume has not

been changed, restore the pair from

the primary array.

PSUE, MCU

IMPL

Primary data

volume,

secondary data

volume

Primary array could not find valid

control information in its nonvolatile

memory during the IMPL procedure.

This error occurs only if the primary

array is without power for more than

48 hours (power failure and fully

discharged batteries).

Restore the pair (pairresync) from the

primary array. The primary array

performs an initial copy operation in

response to the pairresync request, so

the entire primary data volume is

copied to the secondary data volume.

PSUE, Initial

Copy Failed

Primary data

volume,

secondary data

volume

Primary array suspended this pair

during the initial copy operation. Data

on the secondary data volume is not

identical to data on the primary data

volume.

Delete the pair from the primary array.

Clear all error conditions at the

primary array, primary data volume,

secondary array, and secondary data

volume. Restart the initial copy

operation using the Paircreate pane.

PSUE, MCU

P/S-OFF

Secondary data

volume

Primary array suspended all

Continuous Access XP Journal pairs

because the primary array was

powered off.

None. Primary array automatically

restores these Continuous Access XP

Journal pairs when the primary array

is powered on.