Link Integrity Parameters
Name
Type
Values
Access CLI Parameter
Link Integrity
Group
N/A
R
linkint
Link Integrity Status
Integer
enable
disable (default)
RW
linkintstatus
Link Integrity Poll
Interval
Integer
500 - 15000 ms
(in increments of 500ms)
500 ms (default)
RW
linkintpollint
Link Integrity Poll
Retransmissions
Integer
0 - 255
5 (default)
RW
linkintpollretx
Link Integrity IP Target Table
Name
Type
Values
Access CLI Parameter
Link Integrity IP Target
Table
Table
N/A
R
linkinttbl
Table Index
Integer
1-5
N/A
index
Target IP Address
IpAddress
User Defined
RW
ipaddr
Comment (optional)
DisplayString
User Defined (up to 254
characters)
RW
cmt
Status (optional)
Integer
enable
disable (default)
delete
RW
status