System parameters, Command line interface (cli) system parameters, C-26 – HP ProCurve 520wl Wireless Access Point User Manual
Page 162
Command Line Interface (CLI)
System Parameters
Name
Type
Values
Access CLI Parameter
System
Group
N/A
R
system
Name
DisplayString
User Defined
RW
sysname
Location
DisplayString
User Defined
RW
sysloc
Contact Name
DisplayString
User Defined
RW
sysctname
Contact E-mail
DisplayString
User Defined
RW
sysctemail
Contact Phone
DisplayString
User Defined
max 254 characters
RW
sysctphone
FLASH Backup Interval
Integer
0 - 65535 seconds
RW
sysflashbckint
Flash Update
0
1
RW
sysflashupdate
System OID
DisplayString
N/A
R
sysoid
Descriptor
DisplayString
System Name, flash
version, S/N, bootloader
version
R
sysdescr
Up Time
Integer
dd:hh:mm:ss
dd – days
hh – hours
mm – minutes
ss – seconds
R
sysuptime
Emergency Restore to defaults
Resets all parameters to
default factory values
RW
sysresettodefaults
Note: You must enter the
following command twice to
reset to defaults:
set sysresettodefaults 1
C-26